title: Shasta Software - Release Notes - V. 2.5.10
description: The release notes for Shasta software version 2.5.9
---

[Skip to content](https://support.sierrabio.com/shasta-software-release-notes-updated#main-content)

English

Show submenu for translations

![](https://support.sierrabio.com/hs-fs/hubfs/JPG%20file%20-02.jpg?width=2000&height=1125&name=JPG%20file%20-02.jpg)

Open main navigation

Close main navigation

- English
  
  Show submenu for translations
- [Contact us](mailto:support@sierrabio.com)

[Contact us](mailto:support@sierrabio.com)

 How can we help you?

- There are no suggestions because the search field is empty.

1. [Sierra Biosystems Support Center](https://support.sierrabio.com/?hsLang=en)
2. [Software Updates & Release Notes](https://support.sierrabio.com/software-updates-release-notes?hsLang=en)
3. [Release Notes](https://support.sierrabio.com/software-updates-release-notes?hsLang=en#release-notes)

June 25, 2026

# Shasta Software - Release Notes - V. 2.5.10

## This article summarizes the software revisions, feature enhancements, and corrections implemented between versions v2.5.5 and v2.5.10

 

### **Software Release Notes**

---

#### **Revision History**

### **Version 2.5.5**

- Corrected button order in the **Sequence Editor** — the Import and Export buttons had been reversed in a prior update.
- Added a new configuration option to **enable pre-priming all tips** prior to each dispense pass (applicable to *Standard* and *Meta* protocols only).
- Updated **Run Synthesis** to automatically **prime all tips ready for dispense** before the start of each dispense-pass series (*Standard* and *Meta* protocols only).

---

### **Version 2.5.6**

- Modified **Run Synthesis** pressure monitoring behavior:
  
    - When pressure goes out of range, the system now **logs the event silently** instead of displaying an interrupting dialog.
    - The synthesis automatically continues once pressure returns to the acceptable range.
    - Other pausable conditions (e.g., *Lid Open*, *Leak Detected*) will still trigger user dialogs requiring acknowledgment before resuming.

---

### **Version 2.5.7**

- Updated **Backup/Restore** functionality to no longer remember the previous archive path or filename.
- Added a new configuration option to **restrict plate movement** unless chamber pressure is within acceptable limits.
- Enhanced the **Manual Control**, **Priming**, and **Calibrate Position** screens to:
  
    - Display current **lid switch** and **chamber pressure** status.
    - Only allow plate motion when both **lid closed** and **pressure OK** conditions are met, based on configuration settings.
- Updated **Dispense Calibration** to move the plate only when lid and pressure conditions are verified as good.

---

### **Version 2.5.8**

- Added advanced **Run Synthesis controls**, allowing users to:
  
    - **Start synthesis** from a specific base.
    - **Pause** before a specified base.
    - **Pause** automatically after a defined number of hours or minutes.

---

### **Version 2.5.9**

- Modified **Run Synthesis** to disable *Pause Before Base X* and *Pause After X Hours/Minutes* features when running **MAP protocols**.

 

---

### **Version 2.5.10** — **Validated Build**

- Changed the Run Synthesis to move the plate to the "View" position at the end of the synthesis instead of a neutral (x=100, y=100) position.

**Status:**  
✅ *Validated build for production and field use (v2.5.10)*

---

#### **Summary of Key Improvements**

- Enhanced **pressure and motion safety interlocks** for improved operator protection.
- Added **flexible synthesis controls** (start/pause/resume logic).
- Improved **UI consistency** across Manual Control, Priming, and Calibration screens.
- Reduced potential for synthesis interruptions due to transient pressure fluctuations.
- Improved **pre-dispense priming reliability** for Standard and Meta protocols.

- [Pre-Installation & Installation](https://support.sierrabio.com/pre-installation-installation?hsLang=en#main-content)

    - [Pre-Installation Requirements](https://support.sierrabio.com/pre-installation-installation?hsLang=en#pre-installation-requirements)
    - [Site & Lab Preparation](https://support.sierrabio.com/pre-installation-installation?hsLang=en#site-lab-preparation)
    - [Installation & Initial Setup](https://support.sierrabio.com/pre-installation-installation?hsLang=en#installation-initial-setup)
- [Troubleshooting & Errors](https://support.sierrabio.com/troubleshooting-errors?hsLang=en#main-content)

    - [Software Errors & Communication Issues](https://support.sierrabio.com/troubleshooting-errors?hsLang=en#software-errors-communication-issues)
    - [Chemistry and Protocol-Related Issues](https://support.sierrabio.com/troubleshooting-errors?hsLang=en#chemistry-and-protocol-related-issues)
    - [K&A - Preventative Maintenance & Quick Fixes](https://support.sierrabio.com/troubleshooting-errors?hsLang=en#ka-preventative-maintenance-quick-fixes)
    - [Shasta - Preventative Maintenance & Quick Fixes](https://support.sierrabio.com/troubleshooting-errors?hsLang=en#shasta-preventative-maintenance-quick-fixes)
    - [Shasta - Hardware Issues](https://support.sierrabio.com/troubleshooting-errors?hsLang=en#shasta-hardware-issues)
- [Training Videos and Guides](https://support.sierrabio.com/training-videos-and-guides?hsLang=en#main-content)

    - [Shasta Software](https://support.sierrabio.com/training-videos-and-guides?hsLang=en#shasta-software)
    - [K&A Next Gen Software](https://support.sierrabio.com/training-videos-and-guides?hsLang=en#ka-next-gen-software)
    - [K&A Legacy Software](https://support.sierrabio.com/training-videos-and-guides?hsLang=en#ka-legacy-software)
    - [K&A - Troubleshooting Videos](https://support.sierrabio.com/training-videos-and-guides?hsLang=en#ka-troubleshooting-videos)
    - [Shasta - Troubleshooting Videos](https://support.sierrabio.com/training-videos-and-guides?hsLang=en#shasta-troubleshooting-videos)
- [Software Updates & Release Notes](https://support.sierrabio.com/software-updates-release-notes?hsLang=en#main-content)

    - [Release Notes](https://support.sierrabio.com/software-updates-release-notes?hsLang=en#release-notes)
    - [Downloads](https://support.sierrabio.com/software-updates-release-notes?hsLang=en#downloads)
    - [Update Instructions](https://support.sierrabio.com/software-updates-release-notes?hsLang=en#update-instructions)
- [Product Documentation & Policies](https://support.sierrabio.com/product-documentation-policies?hsLang=en#main-content)

    - [Technical Documentation](https://support.sierrabio.com/product-documentation-policies?hsLang=en#technical-documentation)
    - [Specifications](https://support.sierrabio.com/product-documentation-policies?hsLang=en#specifications)
    - [Warranty & Service](https://support.sierrabio.com/product-documentation-policies?hsLang=en#warranty-service)
- [Oligonucleotide Chemistry & Methods](https://support.sierrabio.com/oligonucleotide-chemistry-methods?hsLang=en#main-content)

    - [Synthesis & Strategy](https://support.sierrabio.com/oligonucleotide-chemistry-methods?hsLang=en#synthesis-strategy)
    - [Post-Synthesis Processing](https://support.sierrabio.com/oligonucleotide-chemistry-methods?hsLang=en#post-synthesis-processing)
    - [Quantitation & QC](https://support.sierrabio.com/oligonucleotide-chemistry-methods?hsLang=en#quantitation-qc)
    - [Special Topics](https://support.sierrabio.com/oligonucleotide-chemistry-methods?hsLang=en#special-topics)
- [Support & Contact](https://support.sierrabio.com/support-contact?hsLang=en)
- [Uncategorized](https://support.sierrabio.com/uncategorized?hsLang=en)

[![](https://support.sierrabio.com/hs-fs/hubfs/JPG%20file%20-02.jpg?width=2000&height=1125&name=JPG%20file%20-02.jpg)](http://sierrabio.com)

[mailto:Support@sierrabio.com](mailto:Support@sierrabio.com) <https://www.linkedin.com/company/sierra-biosystems-inc>

Copyright © 2025, Sierra BioSystems